Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38127075

RESUMO

OBJECTIVES: To assess the incidence (1 year) and the cumulative incidence (3 years) of the condition of patients accruing cumulative effective doses (CED) of ≥ 100 mSv and their variability among different hospitals. To establish and validate a reference level for the CED in patients with recurrent exposures (RERL) and provide a RERL value. METHODS: Data of CT exposure was collected in 9 similar hospitals. The database included 294,222 patient*years who underwent 442,278 CT exams in 3 years. The incidence proportion of patients with CED ≥ 100 mSv in a given year (I100;1) and the 3-year cumulative incidence of patients with CED ≥ 100 mSv over 3 consecutive years (I100;3) were calculated and compared among different institutions. RESULTS: I100;1 ranged from a minimum of 0.1% to a maximum of 5.1%. The percentage of recurrent patients was quite uniform among centres ranging from 23 to 38%. The I100;3 ranged from a minimum of 1.1 to 11.4%. There was a strong positive correlation between the third quartile values of yearly CED and yearly incidence (r = 0.90; R2 = 0.81; p < 0.0001). RERL value in our study was found at 34.0 mSv. CONCLUSION: The management of patients with recurrent exposures is highly variable among hospitals leading to a 50-fold variation in I100;1 and to a tenfold variation in I100;3. RERL could be established and used by taking as a RERL quantity the CED and as a RERL value the 75th percentile of the third quartiles of the distribution of the yearly CED obtained by surveying different hospitals. CLINICAL RELEVANCE STATEMENT: This is the first ever multicentre study that quantifies recurrent exposures in terms of incidence and cumulative incidence of patients with CED ≥ 100 mSv. RERL establishment and use could benefit the optimisation of radioprotection of patients with recurrent exposures. KEY POINTS: This is the first multicentre study estimating yearly incidence and 3-year cumulative incidence of patients with cumulative effective doses ≥ 100 mSv. In this study, a 50-fold inter centre variation between the maximum (5.1%) and the minimum value (0.1%) of yearly incidence of patients with cumulative effective doses ≥ 100 mSv was reported. The range of the 3-year cumulative incidence extended from 1.1 to 11.4% (a tenfold variation) The third quartile of the yearly cumulative effective doses in a centre showed a strong positive correlation with the yearly incidence of patients with cumulative effective doses ≥ 100 mSv, with a potential of being used to set reference levels for recurrent exposures.

2.
Radiol Case Rep ; 17(10): 3490-3494, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35912297

RESUMO

A wide spectrum of anomalies of the pancreas, the pancreatic ductal system and the biliary tree are commonly encountered at radiologic evaluation. Pancreas bifidum, also known as bifid pancreas or fish-tail pancreas, is an extremely rare congenital branching anomaly of the main pancreatic duct characterized by its duplication. These 2 separate ducts are laid from the pancreatic tail to neck and they generally join at the pancreas body-tail draining via the major papilla; the pancreatic parenchyma is also bifurcated with separated dorsal and caudal buds. The clinical impact of this condition is not well established: although some authors sustained that probably does not cause or contribute to abdominal pain or overt pancreatic diseases, others argued that could be considered as a possible cause of acute pancreatitis. We herewith describe the case of a 51-year-old woman presenting to our hospital with epigastric pain, nausea, and vomiting. Biochemical tests were suspicious for acute pancreatitis. Ultrasound examination was negative. MRI, including MR cholangiopancreatography revealed bifid pancreas characterized by duplication of the main pancreatic duct with 2 separate ducts that join at the pancreas head and draining via the minor papilla. On T2-weighted images the ventral bud of the pancreas was enlarged and characterized by slightly hyperintensity without peripancreatic fluid collections. The MRI findings were consistent with acute pancreatitis limited to the ventral bud of a bifid pancreas. Patient was treated with intravenous fluid resuscitation, pain control and institution of early enteral nutrition and discharged on the seventh day after admission.

3.
Diseases ; 9(3)2021 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-34562969

RESUMO

Congenital coronary artery anomalies are rare but well-described causes of chest pain and, in some cases, link to sudden cardiac death. With the spread of advanced imaging techniques, the number of incidental findings is staggering, but little information has been given in order to rule out potential malignant cases in symptomatic adult patients. Here, we describe a case of an anomalous course of the coronary artery with an acute (<45°) take-off angle, as well as an inter-arterial course between a dilated ascending aorta and a dilated pulmonary artery, and how we could manage this patient in our clinical practice.

4.
Radiol Med ; 122(8): 568-574, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28429205

RESUMO

PURPOSE: To compare the lung nodules' detection of digital tomosynthesis (DTS) and computed tomography (CT) in the context of the SOS (Studio OSservazionale) prospective screening program for lung cancer detection. MATERIALS AND METHODS: One hundred and thirty-two of the 1843 subjects enrolled in the SOS study underwent CT because non-calcified nodules with diameters larger than 5 mm and/or multiple nodules were present in DTS. Two expert radiologists reviewed the exams classifying the nodules based on their radiological appearance and their dimension. LUNG-RADS classification was applied to compare receiver operator characteristics curve between CT and DTS with respect to final diagnosis. CT was used as gold standard. RESULTS: DTS and CT detected 208 and 179 nodules in the 132 subjects, respectively. Of these 208 nodules, 189 (91%) were solid, partially solid, and ground glass opacity. CT confirmed 140/189 (74%) of these nodules but found 4 nodules that were not detected by DTS. DTS and CT were concordant in 62% of the cases applying the 5-point LUNG-RADS scale. The concordance rose to 86% on a suspicious/non-suspicious binary scale. The areas under the curve in receiver operator characteristics were 0.89 (95% CI 0.83-0.94) and 0.80 (95% CI 0.72-0.89) for CT and DTS, respectively. The mean effective dose was 0.09 ± 0.04 mSv for DTS and 4.90 ± 1.20 mSv for CT. CONCLUSIONS: The use of a common classification for nodule detection in DTS and CT helps in comparing the two technologies. DTS detected and correctly classified 74% of the nodules seen by CT but lost 4 nodules identified by CT. Concordance between DTS and CT rose to 86% of the nodules when considering LUNG-RADS on a binary scale.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...